Selection Of Double Acting Actuator:
The suggested safety factor for double acting actuators under normal working conditions is 20%~30%.
Example:
- The torque needed by valve=100Nm.
- The torque considered safety factor (1+30%)=130Nm
- Air Supply=5bar
- According the below table, we can choose the minimum model is AT160DA.
-
- Output Torque Of Double Acting Actuators:
Selection Of Single Acting Actuator:
The suggested safety factor for spring return actuator under normal working conditions is 30%~50%.
Example:
- The torque needed by valve=80Nm
- The torque consider safety factor=80(1+30%)=104Nm
- Air Supply=5bar
- According to the below table, we find output torque of AT140SR K7 is:
- Air stroke 0°=308Nm
- Air stroke 90°=247Nm
- Spring stroke 0°=120Nm
- Spring stroke 90°=181Nm
- All the output torque is large than we needed.
- Output Torque Of Spring Return Actuators: